FM-quiz BasPhys
Quiz Summary
0 of 14 questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 14 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Multiple Choice 0%
- Summary 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- Current
- Review
- Answered
- Correct
- Incorrect
- Question 1 of 14
1. Question
Sound wave characteristics. What is hertz the SI unit of?
CorrectIncorrect - Question 2 of 14
2. Question
Attenuation. Insert the correct missing words: Attenuation depends on the ……….. the sound wave.
CorrectIncorrect - Question 3 of 14
3. Question
Reflection. What is the reflection of a sound wave at an interface in a medium a function of?
CorrectIncorrect - Question 4 of 14
4. Question
Transducer orientation. The image on the left shows correct and inverted orientation of the transducer. Which of the following statements are correct? Select all that apply.
CorrectIncorrect - Question 5 of 14
5. Question
Depth and gain A. The image shows two ultrasound images, where B is an optimised image of A. How is B optimised ?
CorrectIncorrect - Question 6 of 14
6. Question
Depth and gain B. The image shows two ultrasound images, where B is an optimised image of A. How is B optimised ?
CorrectIncorrect - Question 7 of 14
7. Question
Doppler. What is true regarding Doppler and blood vessels? Select all that apply.
CorrectIncorrect - Question 8 of 14
8. Question
Transmission of sound. Transmission of sound in a medium is due to …
CorrectIncorrect - Question 9 of 14
9. Question
Rarefaction. Select the correct word to fill the gap: Rarefaction is regions of …….. of the sound pressure within the carrier medium.
CorrectIncorrect - Question 10 of 14
10. Question
Match the phrase at the top with the correct option below to form true statements by dragging the answer into the answer box.
Sort elements
- acoustic impedance
- vacuum
- medium
- amplitude
- deeper than high frequencies
- Reflection is determined by
- The only place in which sound cannot travel is in a
- The substance or material that carries the wave is called a
- Maximum oscillation of a sound wave is called
- Low frequencies penetrate
CorrectIncorrect - Question 11 of 14
11. Question
Match the phrase at the top with the correct option below to form true statements by dragging the answer into the answer box.
Sort elements
- the use of ultrasound gel
- do not reflect sound waves
- synonymous with reflected sound
- diffuse reflection
- sound
- An example of impedance matching is
- Tissues with same acoustic impedance
- Echo is
- Scattering is
- Ultrasound is
CorrectIncorrect - Question 12 of 14
12. Question
Match the phrase at the top with the correct option below to form true statements by dragging the answer into the answer box.
Sort elements
- generates high voltage spikes of 100-900 V
- converts electrical energy to ultrasound waves
- along the long axis of the ultrasound beam
- in the plane perpendicular to the long axis of the ultrasound beam
- the piezoelectric crystals are arranged in a straight array
- The transmitter
- The transducer
- Axial resolution is the ability to separate two objects
- Lateral resolution is the ability to separate two objects
- In linear transducers
CorrectIncorrect - Question 13 of 14
13. Question
Match the phrase at the top with the correct option below to form true statements by dragging the answer into the answer box.
Sort elements
- no echo
- high intensity echo
- time
- amplitude
- in the focal zone
- In B-mode a dark area represents
- In B-mode a bright area represents
- In M-mode the x axis represents
- In M-mode the y axis represents
- The sound field is most narrow
CorrectIncorrect - Question 14 of 14
14. Question
Match the phrase at the top with the correct option below to form true statements by dragging the answer into the answer box.
Sort elements
- is abbreviated OM
- a 1.5 – 4 MHz multifrequency phased array transducer is recommended
- is on the right side of the screen
- is on the left side of the screen
- adjust gain at different depths of the ultrasound image
- The orientation marker on the transducer
- For FATE examination
- In cardiac ultrasound the orientation indicator (OI)
- In FAST ultrasound the orientation indicator (OI)
- Time gain compensation (TGC) can
CorrectIncorrect
